DRTU24D06 Crydom - Relays
DRTU24D06 Description
Rated at 280 V and 6 A, the Crydom DRTU24D06 is a solid state relay. Solid state relays like this switch heaters, motors, lamps and other loads quietly and without contact wear.
USComponent has been supplying power semiconductors since 2001, including discontinued and hard-to-find part numbers. Send us an RFQ for the DRTU24D06 and we will reply with price, condition and lead time. Please check the manufacturer's datasheet to confirm ratings, package and pin-out before you order.
Summary of Features
Crydom DRTU24D06 is a 6 A SeriesOne DR solid state timer relay (11 mm wide DIN rail), timing function multifunction (A/At, H/Ht, D/Di, B, C, Ac and Bw), AC output 24-280 VAC, control 12-24 VAC/DC, zero voltage turn-on.
Target Applications
Crydom DRTU24D06 is used for time-delayed switching of heaters, motors, lamps and other loads in industrial control, HVAC and process equipment.
Key Specifications
Crydom DRTU24D06 is a 6 A SeriesOne DR solid state timer relay (11 mm wide DIN rail), timing function multifunction (A/At, H/Ht, D/Di, B, C, Ac and Bw), AC output 24-280 VAC, control 12-24 VAC/DC, zero voltage turn-on. Source: Crydom SeriesOne DR Timer datasheet (Rev. 100312). Values at 25°C unless noted.
| Parameter | Value |
|---|---|
| Output | |
| Operating voltage | 24-280 VAC (47-440 Hz) |
| Rated load current | 6 Arms |
| Rated load current (UL 508 motor controller) | 3.6 Arms |
| Transient overvoltage | 600 Vpk |
| Minimum load current | 150 mArms |
| Maximum off-state leakage | 0.1 mArms |
| Minimum off-state dv/dt | 500 V/µs |
| Maximum surge current (1 cycle) | 285/300 Apk (50/60 Hz) |
| Maximum I²t for fusing | 410/375 A²s (50/60 Hz) |
| Maximum on-state voltage drop | 1.3 Vpk |
| HP rating (UL 508 / IEC 60947) @ 240 VAC | 1/3 HP (0.24 kW) |
| Input | |
| Control voltage range | 12-24 VAC/DC |
| Timing function | multifunction (A/At, H/Ht, D/Di, B, C, Ac and Bw) |
| LED status indicator | Green |
| General | |
| Dielectric strength, input/output/base | 3750 Vrms |
| Ambient operating temperature | -30 to 80°C |
| Weight (typical) | 1.76 oz (50 g) |
Technical document (PDF) | Request a quote for DRTU24D06 (reply within 24 hours)
Related Part Numbers
| DRTU06D06 60(V) / 6(A) | DRTU24A06 280(V) / 6(A) | DRTL24D06 280(V) / 6(A) | DRTL24A06 280(V) / 6(A) |
| DRTL06D06 60(V) / 6(A) | DRTH24D06 280(V) / 6(A) | DRTH24A06 280(V) / 6(A) | DRTH06D06 60(V) / 6(A) |
| DRTC24D06 280(V) / 6(A) | DRTC24A06 280(V) / 6(A) | DRTC06D06 60(V) / 6(A) | DRTB24D06 280(V) / 6(A) |
| DRTB24A06 280(V) / 6(A) | DRTB06D06 60(V) / 6(A) | DRTA24D06 280(V) / 6(A) | DRTA24A06 280(V) / 6(A) |