LCB126 Crydom - Relays
LCB126 Description
The LCB126 from Crydom is a solid state relay. Typical uses include temperature control of heaters, packaging and plastics machinery, and general industrial load switching.
USComponent has sourced power semiconductors for maintenance teams and OEMs since 2001. For price and availability of the LCB126, send us a request for quote. Please confirm the specifications against the manufacturer's datasheet before purchase.
Summary of Features
Crydom LCB126 is a 1 Form B (normally closed) PhotoMOS solid state relay, 250 V peak switching voltage.
Target Applications
Crydom LCB126 is used for low-level signal and small load switching on circuit boards in telecom, test and measurement, security systems, metering and industrial control electronics.
Key Specifications
Crydom LCB126 is a 1 Form B (normally closed) PhotoMOS solid state relay, 250 V peak switching voltage. Source: Crydom PhotoMOS Form B datasheet. Values at 25°C unless noted.
| Parameter | Value |
|---|---|
| Output | |
| Switching voltage (max) | 250 Vpk |
| Switching current (max) | 200 / 400 mA |
| On resistance (max) | 13 / 3.25 Ohm |
| Off-state leakage (max, VL = max) | 1.0 µA |
| Turn-on / turn-off time (max) | 5.0 ms / 1.0 ms |
| Input (LED) | |
| LED forward current to turn off the output (turn on LED, max) | 5.0 mA |
| Recommended forward current | 10-30 mA |
| LED forward voltage (IF = 20 mA) | 1.1-1.4 V |
| General | |
| Dielectric strength, input to output (60 s) | 3750 Vrms |
| Power dissipation (max) | 500 mW |
Technical document (PDF) | Request a quote for LCB126 (reply within 24 hours)
Related Part Numbers
| LCB110 350V, 165mA | LCB126S 250V, 200mA | LCB110S 350V, 165mA | LCB110ST 350V, 165mA |
| LCHA-A1-04 | LCA220S 15(V) / 250(A) | LCA220 15(V) / 250(A) | LCA120L 250V, 150mA |
| LCA110LSTR 400V, 120mA | LCA110LS 400V, 120mA | LCA110L 400V, 120mA | LC242R 12-280VAC, 2A |
| LC242 12-280VAC, 2A | LC241R 12-280VAC, 1.5A | LC241-7441 240V) / 1.5(A) | LC241 12-280VAC, 1.5A |