CWA48125-10 Crydom - Relays

CWA48125-10 Crydom Relays

We beat competitor's price with faster delivery.

For 6 pieces or more, submit your inquiry here, email to sales@uscomponent.com or call 1-281-968-0718

CWA48125-10 Description

The CWA48125-10 from Crydom is a solid state relay. It is widely used for heater control, motor switching, lighting and process equipment where mechanical contacts would wear out.

USComponent has sourced power semiconductors for maintenance teams and OEMs since 2001. For price and availability of the CWA48125-10, send us a request for quote. Please confirm the specifications against the manufacturer's datasheet before purchase.

Summary of Features

Crydom CWA48125-10 is a 125 A panel-mount solid state relay, CW48 Series (48-660 VAC), SCR output, AC control (90-280 VAC), instantaneous (random) turn-on, with LED status indicator and IP20 touch-safe cover.

Target Applications

Crydom CWA48125-10 is used for switching AC loads in industrial heating and temperature control (ovens, furnaces, plastic molding and extrusion machines), packaging and food processing equipment, lighting control, HVAC systems and industrial automation.

Key Specifications

Crydom CWA48125-10 is a 125 A panel-mount solid state relay, CW48 Series (48-660 VAC), SCR output, AC control (90-280 VAC), instantaneous (random) turn-on, with LED status indicator and IP20 touch-safe cover. Source: Crydom CW48 Series datasheet (FDE-07-01 Rev. A). Values at 25°C unless noted.

ParameterValue
Output
Operating voltage (47-440 Hz)48-660 Vrms
Maximum load current125 Arms
Transient overvoltage1200 Vpk
Minimum load current250 mArms
Maximum 1-cycle surge current (50/60 Hz)1900/2000 Apk
Maximum on-state voltage drop @ rated current1.25 Vpk
Maximum off-state leakage @ rated voltage1 mArms
Minimum off-state dv/dt500 V/µs
Maximum I²t for fusing, 1/2 cycle (50/60 Hz)18000/16600 A²s
Thermal resistance junction to case (Rjc)0.11 °C/W
Motor rating (UL 508 / IEC 60947)5 HP @ 120 VAC, 10 HP @ 240 VAC, 15 HP @ 480 VAC
Switching typeinstantaneous (random) turn-on
Input
Control voltage range90-280 VAC
Minimum turn-on voltage90 VAC
Must turn-off voltage10 VAC
Input current6-10 mA
Maximum turn-on / turn-off time20 ms / 30 ms
General
Dielectric strength, input/output/base4000 Vrms
Ambient operating temperature-40 to 80°C
LED input status indicatorGreen
Weight (typical)2.88 oz (81.53 g)

Technical document (PDF)  |  Request a quote for CWA48125-10 (reply within 24 hours)