CSE2410 Crydom - Relays

Category: Solid State Relays & I/O Modules

Specifications: 240(V) / 10(A)

CSE2410 Crydom Relays

We beat competitor's price with faster delivery.

For 6 pieces or more, submit your inquiry here, email to sales@uscomponent.com or call 1-281-968-0718

CSE2410 Description

The CSE2410 from Crydom is a solid state relay with a 240 V / 10 A rating. Typical uses include temperature control of heaters, packaging and plastics machinery, and general industrial load switching.

USComponent has been supplying power semiconductors since 2001, including discontinued and hard-to-find part numbers. Send us an RFQ for the CSE2410 and we will reply with price, condition and lead time. Please check the manufacturer's datasheet to confirm ratings, package and pin-out before you order.

Summary of Features

Crydom CSE2410 is a 10 A panel-mount solid state relay (CSE Series, 24-280 VAC, snubberless / low leakage), SCR output, DC control 15-32 VDC, zero voltage turn-on. The datasheet marks this series obsolete (replaced by CSW).

Target Applications

Crydom CSE2410 is used for switching AC loads in industrial heating and temperature control (ovens, furnaces, plastic molding and extrusion machines), packaging and food processing equipment, lighting control, HVAC systems and industrial automation.

Key Specifications

Crydom CSE2410 is a 10 A panel-mount solid state relay (CSE Series, 24-280 VAC, snubberless / low leakage), SCR output, DC control 15-32 VDC, zero voltage turn-on. The datasheet marks this series obsolete (replaced by CSW). Source: Crydom CSE Series datasheet. Values at 25°C unless noted.

ParameterValue
Output
Operating voltage (47-440 Hz)24-280 Vrms
Maximum load current10 Arms
Transient overvoltage600 Vpk
Minimum load current0.15 Arms
Maximum 1 cycle surge current (50/60 Hz)115/120 Apk
Maximum on-state voltage drop @ rated current1.6 Vpk
Maximum off-state leakage @ rated voltage1.0 mArms
Minimum off-state dv/dt500 V/µs
Thermal resistance junction to case (Rjc)1.48 °C/W
Maximum I²t for fusing (1/2 cycle, 50/60 Hz)66/60 A²s
Switching typezero voltage turn-on
Input
Control voltage range15-32 VDC
Minimum turn-on / turn-off voltage15.0 / 1.0 VDC
Typical input current7 mA @ 15 V
Nominal input impedance2 kOhm
Maximum turn-on / turn-off time1/2 cycle / 1/2 cycle
General
Dielectric strength, input/output/base4000 Vrms
Ambient operating temperature-40 to 80°C
Weight (typical)3.0 oz (86.5 g)

Technical document (PDF)  |  Request a quote for CSE2410 (reply within 24 hours)