HA6050 Crydom - Relays
HA6050 Description
Crydom makes the HA6050, a 600 V, 50 A solid state relay. Solid state relays like this switch heaters, motors, lamps and other loads quietly and without contact wear.
Request a quote for the HA6050 and our team will get back to you with price, quantity available and lead time. We ship worldwide. As with any power device, please check the manufacturer's datasheet to confirm it matches your design.
Summary of Features
Crydom HA6050 is a 50 A panel-mount solid state relay, HA/HD60 Series (48-660 VAC), SCR output, AC control (90-280 VAC), zero voltage turn-on.
Target Applications
Crydom HA6050 is used for switching AC loads in industrial heating and temperature control (ovens, furnaces, plastic molding and extrusion machines), packaging and food processing equipment, lighting control, HVAC systems and industrial automation.
Key Specifications
Crydom HA6050 is a 50 A panel-mount solid state relay, HA/HD60 Series (48-660 VAC), SCR output, AC control (90-280 VAC), zero voltage turn-on. Source: Crydom HA/HD60 Series datasheet. Values at 25°C unless noted.
| Parameter | Value |
|---|---|
| Output | |
| Operating voltage (47-440 Hz) | 48-660 Vrms |
| Maximum load current | 50 Arms |
| Transient overvoltage | 1200 Vpk |
| Minimum load current | 150 mArms |
| Maximum 1-cycle surge current (50/60 Hz) | 597/625 Apk |
| Maximum on-state voltage drop @ rated current | 1.15 Vrms |
| Maximum off-state leakage @ rated voltage | 1.0 mArms |
| Minimum off-state dv/dt | 500 V/µs |
| Maximum I²t for fusing, 1/2 cycle (50/60 Hz) | 1770/1629 A²s |
| Thermal resistance junction to case (Rjc) | 0.45 °C/W |
| Switching type | zero voltage turn-on |
| Input | |
| Control voltage range | 90-280 Vrms |
| Minimum turn-on voltage | 90 Vrms |
| Must turn-off voltage | 10 Vrms |
| Input current | 5-10 mA |
| Maximum turn-on / turn-off time | 20 ms / 30 ms |
| General | |
| Dielectric strength, input/output/base | 4000 Vrms |
| Ambient operating temperature | -40 to 80°C |
| Weight (typical) | 2.6 oz (74.9 g) |
Technical document (PDF) | Request a quote for HA6050 (reply within 24 hours)