HA48125E-10 Crydom - Relays

Category: Solid State Relays & I/O Modules

Specifications: 480(V) / 125(A)

HA48125E-10 Crydom Relays

Availability and lead time are confirmed in our quote.

  • ✓ Quote within 24 hours
  • ✓ Original manufacturer parts, inspected before shipping
  • ✓ Credit cards and NET terms accepted

Or email sales@uscomponent.com or call 1-281-968-0718.

HA48125E-10 Description

Crydom HA48125E-10 is a solid state relay rated at 480 V and 125 A. It is widely used for heater control, motor switching, lighting and process equipment where mechanical contacts would wear out.

Looking for a replacement HA48125E-10? USComponent can quote new and hard-to-find stock and ships worldwide. Request a quote for pricing and lead time, and double-check the datasheet to make sure it fits your application.

Summary of Features

Crydom HA48125E-10 is a 125 A panel-mount solid state relay, HA/HD48 Series (48-530 VAC), SCR output, AC control (18-36 VAC), instantaneous (random) turn-on.

Target Applications

Crydom HA48125E-10 is used for switching AC loads in industrial heating and temperature control (ovens, furnaces, plastic molding and extrusion machines), packaging and food processing equipment, lighting control, HVAC systems and industrial automation.

Key Specifications

Crydom HA48125E-10 is a 125 A panel-mount solid state relay, HA/HD48 Series (48-530 VAC), SCR output, AC control (18-36 VAC), instantaneous (random) turn-on. Source: Crydom HA/HD48 Series datasheet. Values at 25°C unless noted.

ParameterValue
Output
Operating voltage (47-440 Hz)48-530 Vrms
Maximum load current125 Arms
Transient overvoltage1200 Vpk
Minimum load current150 mArms
Maximum 1-cycle surge current (50/60 Hz)1670/1750 Apk
Maximum on-state voltage drop @ rated current1.15 Vrms
Maximum off-state leakage @ rated voltage1 mArms
Minimum off-state dv/dt500 V/µs
Maximum I²t for fusing, 1/2 cycle (50/60 Hz)13950/12709 A²s
Thermal resistance junction to case (Rjc)0.22 °C/W
Switching typeinstantaneous (random) turn-on
Input
Control voltage range18-36 Vrms
Minimum turn-on voltage18 Vrms
Must turn-off voltage4 Vrms
Input current16-20 mA
Maximum turn-on / turn-off time20 ms / 30 ms
General
Dielectric strength, input/output/base4000 Vrms
Ambient operating temperature-40 to 80°C
Weight (typical)2.6 oz (74.9 g)

Technical document (PDF)  |  Request a quote for HA48125E-10 (reply within 24 hours)

Related Part Numbers

HA48110E-10
480(V) / 110(A)
HA60125E-10
600(V) / 125(A)
HA6090E-10
600(V) / 90(A)
HA6050E-10
600(V) / 50(A)
HA6025E-10
600(V) / 25(A)
HA4890E-10
480(V) / 90(A)
HA4875E-10
480(V) / 75(A)
HA4850E-10
480(V) / 50(A)
HA4812E
480(V) / 12(A)
HA48125E
480(V) / 125(A)
HA4812E-10
480(V) / 12(A)
HA48125-10
480(V) / 125(A)
HA4812F
480(V) / 12(A)
HA48125
480(V) / 125(A)
HA4812-10
480(V) / 12(A)
HA4812
480(V) / 12(A)