D4850 Crydom - Relays
D4850 Description
The Crydom D4850 is a solid state relay, rated for 480 V and 50 A. It is widely used for heater control, motor switching, lighting and process equipment where mechanical contacts would wear out.
We help engineers and repair technicians find parts like the D4850, including obsolete ones. Send a quick RFQ for current pricing and delivery. Before ordering, please confirm ratings and pin-out with the official datasheet.
Summary of Features
Crydom D4850 is a 50 A panel-mount solid state relay, Series 1 480 VAC (48-530 VAC), SCR output, DC control, zero voltage turn-on.
Target Applications
Crydom D4850 is used for switching AC loads in industrial heating and temperature control (ovens, furnaces, plastic molding and extrusion machines), packaging and food processing equipment, lighting control, HVAC systems and industrial automation.
Key Specifications
Crydom D4850 is a 50 A panel-mount solid state relay, Series 1 480 VAC (48-530 VAC), SCR output, DC control, zero voltage turn-on. Source: Crydom Series 1 480 VAC datasheet. Values at 25°C unless noted.
| Parameter | Value |
|---|---|
| Output | |
| Operating voltage (47-440 Hz) | 48-530 Vrms |
| Maximum load current | 50 Arms |
| Transient overvoltage | 800 Vpk |
| Minimum load current | 150 mArms |
| Maximum 1-cycle surge current (50/60 Hz) | 597/625 Apk |
| Maximum on-state voltage drop @ rated current | 1.15 Vrms |
| Maximum off-state leakage @ rated voltage | 1 mArms |
| Minimum off-state dv/dt | 500 V/µs |
| Maximum I²t for fusing, 1/2 cycle (50/60 Hz) | 1770/1621 A²s |
| Thermal resistance junction to case (Rjc) | 0.45 °C/W |
| Switching type | zero voltage turn-on |
| Input | |
| Control voltage range | 4-32 VDC |
| Minimum turn-on voltage | 4.0 VDC |
| Must turn-off voltage | 1.0 VDC |
| Input current | 7-12 mA |
| Maximum turn-on / turn-off time | 1/2 cycle / 1/2 cycle |
| General | |
| Dielectric strength, input/output/base | 4000 Vrms |
| Ambient operating temperature | -40 to 80°C |
| Weight (typical) | 2.6 oz (74.9 g) |
Technical document (PDF) | Request a quote for D4850 (reply within 24 hours)