CL240D10RC Crydom - Relays

Category: Solid State Relays & I/O Modules

Specifications: 240(V) / 10(A)

CL240D10RC Crydom Relays

We beat competitor's price with faster delivery.

For 6 pieces or more, submit your inquiry here, email to sales@uscomponent.com or call 1-281-968-0718

CL240D10RC Description

Crydom CL240D10RC is a solid state relay rated at 240 V and 10 A. Typical uses include temperature control of heaters, packaging and plastics machinery, and general industrial load switching.

USComponent has been supplying power semiconductors since 2001, including discontinued and hard-to-find part numbers. Send us an RFQ for the CL240D10RC and we will reply with price, condition and lead time. Please check the manufacturer's datasheet to confirm ratings, package and pin-out before you order.

Summary of Features

Crydom CL240D10RC is a 10 A panel-mount solid state relay (CL Series, 24-280 VAC), SCR output, DC control 3-32 VDC, random turn-on, with IP20 cover.

Target Applications

Crydom CL240D10RC is used for switching AC loads in industrial heating and temperature control (ovens, furnaces, plastic molding and extrusion machines), packaging and food processing equipment, lighting control, HVAC systems and industrial automation.

Key Specifications

Crydom CL240D10RC is a 10 A panel-mount solid state relay (CL Series, 24-280 VAC), SCR output, DC control 3-32 VDC, random turn-on, with IP20 cover. Source: Crydom CL Series datasheet (Rev. 120811). Values at 25°C unless noted.

ParameterValue
Output
Operating voltage (47-63 Hz)24-280 Vrms
Maximum load current10 Arms
Transient overvoltage600 Vpk
Minimum load current150 mArms
Maximum surge current (50/60 Hz, 1 cycle)84/100 Apk
Maximum on-state voltage drop @ rated current1.5 Vpk
Maximum off-state leakage @ rated voltage7 mArms
Minimum off-state dv/dt500 V/µs
Thermal resistance junction to case (Rjc)2.5 °C/W
Maximum I²t for fusing (50/60 Hz, 1/2 cycle)48/40 A²s
Switching typerandom turn-on
Input
Control voltage range3-32 VDC
Turn-on / turn-off voltage3.0 / 1.0 VDC
Typical input current @ max turn-on voltage14 mA
Maximum turn-on / turn-off time1/2 cycle / 1/2 cycle
General
Dielectric strength, input/output/base4000 Vrms
Ambient operating temperature-30 to 80°C
Weight (typical)2.8 oz (79 g)

Technical document (PDF)  |  Request a quote for CL240D10RC (reply within 24 hours)