1A500-230HFRLP2 AEG - Thyro Power Controller
1A500-230HFRLP2 Description
AEG makes the 1A500-230HFRLP2, a thyristor power controller. Typical applications are industrial heating, furnace control, drying lines and infrared heating systems.
USComponent is a BBB A+ accredited distributor that specializes in power modules and industrial components, new and legacy. Ask us for a quote on the 1A500-230HFRLP2; we ship worldwide. Please verify the ratings and package against the manufacturer's datasheet first.
Target Applications
AEG 1A500-230HFRLP2 is used for power control of electrical heating in industrial furnaces and ovens, glass manufacturing equipment, plastic extruders and presses, automotive paint drying lines, chemical pipe trace heating, packaging shrink tunnels and infrared drying in printing machines.
Key Specifications
AEG 1A500-230HFRLP2 is a Thyro-AX single-phase digital thyristor (SCR) power controller, 500 V, 230 A, with integrated semiconductor fuse (H), fault relay (R), load monitoring (L) and power control (P), forced ventilation (F). Source: AEG / Advanced Energy Thyro-AX datasheet (ENG-Thyro-AX-231-01).
| Parameter | Value |
|---|---|
| Ratings | |
| Series | Thyro-AX (H RLP2) |
| Phase version | 1A: single-phase |
| Rated voltage | 500 V (operating range 24-550 V) |
| Rated current | 230 A |
| Mains frequency | 47-63 Hz |
| Cooling | Forced ventilation (fan) |
| Load types | Ohmic loads (Rwarm/Rcold up to 6, limitation 3 x Inom) and transformer loads |
| Functions | |
| Operating modes | TAKT, VAR, QTM, SWITCH |
| Control types | Ueff / U²eff / Ieff / I²eff / P |
| Set point inputs | 2 analog set point inputs (0(4)-20 mA, 0(1)-5 V, 0(2)-10 V), 2 digital inputs, 1 switch input |
| Load monitoring | Adjustable response threshold |
| Current limitation | Ieff; current peak limitation to 3 x Inom in VAR mode |
| Relay output | Changeover, max. 250 V, 4 A, 180 W, 1500 VA |
| Analog outputs | 3, each 0(2)-10 V / 0(4)-20 mA |
| External supply | 85-265 V (47-63 Hz) |
| Integrated fuse | Semiconductor fuse (H) |
| Bus interface (optional module) | PROFIBUS DPV1, PROFINET, Modbus RTU/TCP, CANopen, DeviceNet, EtherNet/IP |
Technical document (PDF) | Request a quote for 1A500-230HFRLP2 (reply within 24 hours)